Change the front-panel display contrast, Change the units of measurement, Configure network settings – HP Designjet T1200 Printer series User Manual

Page 37

Advertising
background image

Change the front-panel display contrast

To change the contrast of the front-panel display, select the Setup menu icon

, then Front panel

options > Select display contrast, and enter a value using the

Up

or

Down

key. Press the

OK

key

to set the value. The default contrast is set to 50.

Change the units of measurement

To change the units of measurement in the front-panel display, select the Setup menu icon

, then

Front panel options > Select units, and select English or Metric. By default the units are set to
metric.

Configure network settings

You can view and configure the network settings from the HP Utility (T1200 series only). Under
Windows, select the Settings tab, then Network Settings. Under Mac OS, select Configuration >
Network Settings. The following settings are available.

IP Configuration method: specify the way to set an IP address, selecting BOOTP, DHCP,
Auto IP or Manual.

Host name: specify an IP name for the network device. The name may contain up to 32 ASCII
characters.

IP address: specify the IP address on the print server. Duplicate IP addresses on a TCP/IP
network are not allowed.

NOTE:

If you change the current IP address and click Apply, the browser loses the current

connection to the print server because it is pointing to the old address. To reconnect, browse to
the new IP address.

Subnet mask: specify a subnet mask, which is a 32-bit number applied to an IP address to
determine which bits specify the network and subnet and which bits uniquely specify the node.

Default gateway: specify the IP address of a router or computer that is used to connect to other
networks or sub-networks. If none exist, use the IP address of the computer or the IP address of
the print server.

Domain name: specify the name of the DNS domain in which the print server resides (for
example, support.hp.com).

NOTE:

The domain name does not include the host name: it is not the fully qualified domain

name, such as printer1.support.hp.com.

Idle timeout: specify the number of seconds that an idle connection is allowed to remain open;
30 is the default value. If set to zero, the timeout is disabled and TCP/IP connections remain
open until closed by the other node (such as a workstation) on the network

Default IP: specify the IP address to use when the print server is unable to obtain an IP address
from the network when powered on or when reconfigured to use BOOTP or DHCP.

Send DHCP requests: specify whether DHCP requests are transmitted when a legacy default
IP address or a default Auto IP is assigned.

To configure the same network settings from the front panel, select the Connectivity menu icon

,

then Fast Ethernet or Gigabit Ethernet > Modify configuration.