HP XP7 Storage User Manual

Page 106

Advertising
background image

Description

Error code

(SSB2)

The specified volume is an S-VOL. The pair cannot be released because the S-VOL is specified as an P-VOL.

B941

The command was rejected because the volume is unpaired.

B945

The specified LU is not defined. The DKC configuration might have been changed. Restart RAID Manager.

B952

The operation cannot run because pair status is either PSUS (by user) or PSUE (because of failure).

B97B

The command was rejected because the volume is unpaired.

B97C

The pair cannot be created because the consistency group number is greater than is allowed.

B990

If this error occurred when you did not specify the consistency group number, Contact HP for assistance.

The Swap Resync operation cannot be performed because the S-VOL is not in Suspended or SSWS status.
(Swap Resync resynchronizes differential data when the S-VOL is swapped for the P-VOL.)

B994

The pair cannot be created because the secondary system path setting is invalid.

B998

The pair cannot be created because Cnt Ac-S Z Asynchronous is not supported.

B99B

The DKC LDEV configuration might have been changed while starting RAID Manager. Restart RAID Manager.

B9BD

The source of the command device has run out. In LUN Manager, set the command device to OFF, then to
ON.

B9C0

The pair cannot be split because the S-VOL and S-VOL were not paired with the specified serial numbers
and SSIDs.

C05E

A request for a Pairsplit-S operation was rejected because the S-VOL and S-VOL were not paired with the
specified serial numbers and SSIDs.

C073

A request for a Paircreate or Pairresync operation was rejected because the Cnt Ac-S Z program product
is not installed.

C075

The pair cannot be split because the S-VOL was not paired with the P-VOL.

C0A1

A request for a Pairsplit-S operation was rejected because the S-VOL was not paired with the P-VOL using
the Paircreate command.

C0A2

The pair cannot be created because the specified DKC is the same for the P-VOL and S-VOL.

C0F2

The pair cannot be resynchronized because the pair was not in the Suspend status.

C162

The pair cannot be created because the S-VOL is not available.

C16B

A request for a Pairsplit-S operation was rejected because the status change of the S-VOL failed.

C184

A request for a Pairsplit-S operation was rejected because the pair status was invalid.

C189

A request for a Pairsplit-S operation was rejected because the corresponding volume or group was changing
status.

C18A

The pair cannot be split because the S-VOL pair status was in transition.

C194

A request for a Pairsplit-r operation was rejected because the pair status was already Suspended (by user)
Suspended (because of failure).

C195

Pair split cannot run because the group includes no pair that can be split.

C198

A request for a Pairsplit-r operation was rejected because the corresponding volume or group was changing
status.

C199

The pair’s status cannot be changed during the power-on processing of the DKC.

C1BE

The command was rejected because it was issued to a non-Cnt Ac-S Z volume.

C1D6

The command was rejected because the specified volume is a P-VOL. If the error occurs when the volume
is unpaired, select the volume in Remote Web Console, release the pair using the Yes option for Delete Pair
by Force in the Pairsplit-S dialog box, and then run the command again.

C211

106 Troubleshooting

Advertising
This manual is related to the following products: