Setting bc options, Figure 40 option screen, Setting a bc option (swap&freeze option) – HP XP Business Copy Software User Manual

Page 73: Bc error codes, Table 25 bc error codes (continued), 40 option screen, 25 bc error codes

Advertising
background image

Business Copy XP user guide for the XP10000/XP12000

73

Setting BC options

You can set the BC options by selecting and/or clearing the option check boxes on the Option screen. To

display the Option screen, click the Option tab on the BC main screen.

Figure 40

Option screen

The Select Option box displays check boxes for the BC options.

NOTE:

More options will be supported in the future. See

BC options

” on page 30 for further

information.

The Apply button applies the option settings in the Select Option box.

Setting a BC option (Swap&Freeze option)

1.

In the BC main screen, click Option to display the Select Option box.
Select the option check box. If you do not want to set any option, clear all check boxes in the Select

Option box.

2.

Click Apply. You can now perform a BC operation with the specified option.

BC error codes

BC displays error messages when error conditions occur during BC operations. The BC Error window

displays the BC error code and message. To display the Error window, select the failed volume in the

Preset Volume list on the BC main screen (Display tab), right-click, and select Detail. The following table

describes the BC error codes and provides instructions for resolving each error condition.

Table 25

BC error codes

Error

Code

Description

Corrective Action

0401

A locking time-out was detected during an internal

processing.

A retry may result in a normal termination. Retry

about five seconds later.

0402

A command (Paircreate, Pairsplit, or Reserve

Volume) could not be completed because it was

not in the SMPL status internally.

A retry may result in a normal termination. Retry

about five seconds later.