Where should the scsi terminator be, Installing tape drive, Figure 9 – HP StoreEver DAT Tape Drives User Manual
Page 25
Advertising
1 and 7. terminated SCSI cable
5. server’s power supply
2 and 4. power cable
6. SCSI controller
3. tape drive
Figure 9 Connecting power and SCSI cables
Where should the SCSI terminator be?
Termination must be present at two and ONLY two positions on the SCSI bus—at the beginning of the
SCSI bus and at the end of the SCSI bus. Termination is normally enabled by default on the HBA and
most internal SCSI cables have a terminator attached. This will usually be a small, rectangular block
of plastic attached to the cable end and marked ‘SCSI Terminator’.
Therefore, assuming the HBA is the first device on the bus, you should check that the second terminator is
placed after the last device, as shown in
on page 25, item 1.
DAT SCSI Tape Drives
25
Advertising
This manual is related to the following products: