POST error messages and beep codes

List of messages:

Introduction to POST error messages.........................................................................................

101

Invalid memory types were found on the same node. Please check DIMM compatibility. - Some
DIMMs may not be used
............................................................................................................

102

Fibre Channel Mezzanine/Balcony Not Supported. ...................................................................

102

Memory found on unpopulated Node. — Processor is required to be installed for memory to be
used.
............................................................................................................................................

102

Mixed processor speeds detected. Please make sure that all processors are the same speed. —
System Halted!
...........................................................................................................................

102

Node Interleaving disabled - Invalid memory configuration......................................................

103

There must be a first DIMM in pair if second DIMM in pair is populated. Second DIMM in pair
ignored.
.......................................................................................................................................

103

Unsupported DIMM(s) found in system. - DIMM(s) may not be used......................................

103

1610-Temperature Violation Detected. - Waiting 5 Minutes for System to Cool......................

103

Introduction to POST error messages

The error messages and codes in this section include all messages generated by
ProLiant servers. Some messages are informational only and do not indicate an
error. A server generates only the codes that are applicable to its configuration
and options.

The following POST messages are new. For a complete listing of error messages,
refer to the POST messages in the HP ProLiant Servers Troubleshooting Guide
located on the Documentation CD or on the HP website
(

http://www.hp.com/support

).

WARNING: To avoid potential problems, ALWAYS read

the warnings and cautionary information in the server
documentation before removing, replacing, reseating, or modifying
system components.