HP ProLiant BL45p Server series User Manual

Page 11

Advertising
background image

Component

identification

11

Activity
LED (1)

Online
LED (2)

Fault LED
(3)

Interpretation

On or
flashing

Flashing Off

Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.

The drive is rebuilding or undergoing capacity expansion.

On Off Off Do not remove the drive.

The drive is being accessed, but (1) it is not configured as part of an
array; (2) it is a replacement drive and rebuild has not yet started; or
(3) it is spinning up during the POST sequence.

Flashing Flashing Flashing Do not remove the drive. Removing a drive may cause data loss

in non-fault-tolerant configurations.

Either (1) the drive is part of an array being selected by an array
configuration utility; (2) Drive Identification has been selected in
HP SIM; or (3) drive firmware is being updated.

Off

Off

On

The drive has failed and has been placed offline.

You may replace the drive.

Off

Off

Off

Either (1) the drive is not configured as part of an array; (2) the drive
is configured as part of an array, but it is a replacement drive that is
not being accessed or being rebuilt yet; or (3) the drive is configured
as an online spare.

If the drive is connected to an array controller, you may replace the
drive online.

Advertising