Storage management utilities, Array management utilities – HP ProLiant DL585 G2 Storage-Server User Manual

Page 39

Advertising
background image

Table 7 Tasks and utilities needed for storage server configuration

Task

Storage management utility

Create disk arrays

HP Array Configuration Utility or Storage Manager

Create logical disks from the array space

HP Array Configuration Utility or Storage Manager

Verify newly created logical disks

Windows Disk Management

Create a volume on the new logical disk

Windows Disk Management

NOTE:

The type of configuration may not apply to all supported storage components and serves only as an

example providing basic guidance.

Create disk arrays—On storage servers with configurable storage, physical disks can be

arranged as RAID arrays for fault tolerance and enhanced performance, and then segmented into

logical disks of appropriate sizes for particular storage needs. These logical disks then become

the volumes that appear as drives on the storage server.

CAUTION:

The first two logical drives are configured for the storage server operating system and should not be

altered in any manner. If the first two logical drives are altered, the system recovery process may not

function properly when using the System Recovery DVD. Do not tamper with the “DON’T ERASE” or

local C: volume. These are reserved volumes and must be maintained as they exist.

The fault tolerance level depends on the amount of disks selected when the array was created. A

minimum of two disks is required for RAID 0+1 configuration, three disks for a RAID 5 configuration,

and four disks for a RAID 6 (ADG) configuration.

Create logical disks from the array space—Select the desired fault tolerance, stripe size, and

size of the logical disk.

Verify newly created logical disks—Verify that disks matching the newly created sizes are

displayed.

Create a volume on the new logical disk—Select a drive letter and enter a volume label, volume

size, allocation unit size, and mount point (if desired).

Storage management utilities

The storage management utilities preinstalled on the storage server include the HP Array Configuration

Utility (ACU).

Array management utilities

Storage devices for RAID arrays and LUNs are created and managed using the array management

utilities mentioned previously. For HP Smart Arrays use the ACU.

NOTE:

The ACU is used to configure and manage array-based storage. Software RAID-based storage servers

use Microsoft Disk Manager to manage storage. You need administrator or root privileges to run the

ACU.