Manual path switching, Manual path switching -21 – HP Hitachi Dynamic Link Manager Software Licenses User Manual

Page 45

Advertising
background image

from an error, and then HDLM automatically places the recovered path online

while a non-owner path is in use, the path will be automatically switched over

from the non-owner path to the owner path that just recovered from the

error.

When the Lightning 9900V series, Hitachi USP series, Universal Storage

Platform V/VM series, Virtual Storage Platform series, VSP G1000 series,
Hitachi AMS2000 series

#1

, Hitachi SMS series

#1

, HUS100 series

#1

, or HUS

VM is being used, all the paths are owner paths. As a result, if the path that

was previously used recovers from an error, and then HDLM automatically

places the recovered path online, the path that is currently being used will

continue to be used (as opposed to switching over to the path that was just

recovered).

When intermittent errors

#2

occur on paths and you are using the automatic

failback function, the path status might frequently alternate between the

online and offline statuses. In such a case, because the performance of I/Os

will most likely decrease, if there are particular paths in which intermittent

errors might be occurring, we recommend that you set up intermittent error

monitoring so you can detect these paths, and then remove them from those

subject to automatic failbacks.

You can specify the automatic failback function or intermittent error by the
dlnkmgr command's set operation. For details on the set operation, see

set

(Sets Up the Operating Environment) on page 6-15

.

#1

This storage system applies when the dynamic I/O path control function is

disabled.

#2

An intermittent error means an error that occurs irregularly because of

some reason such as a loose cable connection.

Manual Path Switching

You can switch the status of a path by manually placing the path online or

offline. Manually switching a path is useful, for example, when system

maintenance needs to be done.

You can manually place a path online or offline by doing the following:

Execute the dlnkmgr command's online or offline operation.
For details on the online operation, see

online (Places Paths Online) on

page 6-10

. For details on the offline operation, see

offline (Places

Paths Offline) on page 6-6

.

However, if there is only one online path for a particular LU, that path cannot

be manually switched offline. Also, a path with an error that has not been

recovered from yet cannot be switched online.

HDLM uses the same algorithms to select the path that will be used next,

regardless of whether automatic or manual path switching is used.

HDLM Functions

2-21

Hitachi Dynamic Link Manager (for Linux®) User Guide

Advertising
This manual is related to the following products: