Cannot connect to the switch snmp interface, Destination device – HP ProLiant xw460c Blade Workstation User Manual

Page 50

Advertising
background image

Troubleshooting 50

The switch IP address is not configured or correct.

From the serial console interface, be sure that the switch IP address is configured and valid on
the network.

Use the correct IP address to establish the SSH connection with the switch.

The setting allowing access to the switch using the SSH interface is disabled.

From the serial console interface, be sure that the SSH interface is enabled and all the settings are
configured correctly.

The management network address/mask (if used) does not contain the IP address of the
management station. From the serial console interface, be sure that the management network
address/mask contains the IP address of the management station.

Cannot connect to the switch SNMP interface

Action:

The switch IP address is not configured or correct.

From the serial console interface, be sure that the switch IP address is configured and valid on
the network.

Use the correct IP address to establish the SNMP connection with the switch.

The management network address/mask (if used) does not contain the IP address of the
management station. From the serial console interface, be sure that the management network
address/mask contains the IP address of the management station.

The port activity LEDs continuously indicate activity after

connecting more than one port to another switch or

destination device

Action:

Because there are multiple links across this device and the destination device, they form loops, which
cause broadcast storms. Enable STP for multiple links. This setting prevents loops and maintains standby
links for resilience in case of primary link failure.

Cannot connect to the switch remotely using the Web

interface

Action:

The switch IP address is not configured or correct.

From the serial console interface, be sure that the switch IP address is configured and valid on
the network.

Use the correct IP address to establish the Web connection with the switch.

Access to the switch using the Web interface is disabled. From the serial console interface, be sure
that the Web interface is enabled.

The Proxy server settings are configured on the Internet browser and the proxy server does not know
the switch IP address. Disable the manual proxy settings on the Web browser and let it automatically
find Web servers using the IP address.

Advertising