301 recovery rom autoflash done, 302 recovery rom autoflash failed, 303 rom cloning started – HP StorageWorks 500 G2 Modular Smart Array User Manual

Page 121

Advertising
background image

Troubleshooting

121

301 Recovery ROM Autoflash Done

Type: Informational

Description: Indicates that the controller successfully completed the process of
copying the current active firmware image into the backup recovery ROM.

Action: None

302 Recovery ROM Autoflash Failed

Type: Informational

Description: Indicates that the controller failed to copy the current active
firmware image into the backup recovery ROM. Recovery ROM support is
disabled.

Action:

1. Remove the failing controller.

2. Wait 10 seconds.

3. Reinstall the controller, and be sure that it seats fully in the chassis.

The controller reattempts the ROM autoflash process again.

If this action does not solve the problem, contact HP support.

303 ROM Cloning Started

Type: Informational

Description: Indicates that the two controllers in an MSA500 G2 storage system
do not have the same version of firmware. Controller Firmware Auto Cloning
begins.

Action: Refer to Controller Firmware Auto Cloning (on page

62

).

Advertising