Is the controller display providing messages, Recognizing hard drive failure – HP StorageWorks 500 G2 Modular Smart Array User Manual

Page 78

Advertising
background image

78

HP StorageWorks MSA500 G2 Storage System User Guide

Is the controller display providing messages?

Answer Possible

Reasons Possible

Solutions

No

The controller may not be inserted
properly, it may have a damaged
connector, or it may have failed.

Be sure that the controller is undamaged and
is fully seated.

Be sure that all pins on connectors and
components are straight.

Contact an authorized service provider for
assistance.

When the controller display is working
properly, refer to the Yes response below.

Yes

Display messages are available for
diagnosis. Determine the next action by
observing the messages ("Display
messages" on
page

85

).

Recognizing hard drive failure

In an HP storage system, a steadily glowing Fault LED indicates that that drive
has failed. When a drive is configured as part of an array and attached to a
powered up controller, the status of the drive can be determined from the
illumination pattern of the controller LEDs (on page

20

).

Other means by which hard drive failure is revealed are:

• The amber LED on the front of a storage system illuminates if failed drives

are inside. (However, this LED also illuminates when other problems occur,
such as when a blower fails, a redundant power supply fails, or the system
overheats.)

• A controller display message lists failed drives whenever the system is

restarted, as long as the controller detects at least one functional drive.

• ACU represents failed drives with a distinctive icon.
• HP SIM can detect failed drives remotely across a network. (For more

information about HP SIM, refer to the documentation on the Management
CD.)