HP ESL E-series Tape Libraries User Manual

Page 68

Advertising
background image

Test

Description

Read Cabinet Type

Verifies that the cabinet type barcode can be read, then

displays the cabinet type.

LTOHPF is an initial full LTO library.

LTOHPC indicates an initial capacity-on-demand LTO

library.

LTO indicates an LTO library purchased before

capacity-on-demand was introduced.

SDLTHPF indicates an initial full SDLT library.

SDLTHPC indicates an initial capacity-on-demand SDLT

library.

SDLT indicates an SDLT library purchased before

capacity-on-demand was introduced.

Force Drive Unload

Clears the Prevent Media Removal bit. Unloads the tape

cartridge to the original slot or to the first empty slot.

CLM Self Test (primary

cabinets only)

Checks for unrestricted motion of the library robotics,

including between cabinets.

CLM to Home Position

(primary cabinets only)

Moves the CLM shuttle along the entire CLM arm, ending

with the shuttle extended into the primary cabinet.

Sequential Slot Test

(standalone or primary

cabinets only)

Performs an inventory of the library, then checks each slot

in the library, sequentially, to determine whether there is

free movement of the tapes in and out of the slots.

Sequential Drive Test

(standalone or primary

cabinets only)

Performs an inventory of the library, then checks drives

in the library, sequentially, to determine whether it is

communicating properly with the drives.

Random Test (standalone or

primary cabinets only)

Performs an inventory of the library, then randomly selects

and runs one of the tests.

Random Slot Test (standalone

or primary cabinets only)

Performs an inventory of the library, then checks a

sampling of slots in the library, in random order, to

determine whether there is free movement of the tapes in

and out of the slots.

Random Slot to Drive Test

(standalone or primary

cabinets only)

Performs an inventory of the library, then checks a

sampling of drives in the library, in random order, to

determine whether it is communicating properly with the

drives and whether there is free movement of the tapes

into and out of the slots.

Element to Element Test

(standalone or primary

cabinets only)

Moves media from any source location to any destination

location in the library, including different cabinets in a

CLM library.

The Sequential Slot Test, Sequential Drive Test, Random Test, Random Slot Test, and Random Slot to Drive

Test can be run from 1-500 times, or continuously until the test is manually ended. For each drive or slot

test, running it once will check one drive or slot, whereas running it 100 times will check 100 drives or

slots. If tests are run more times than there are drives or slots, the library will test drives or slots multiple

times until it has performed the requested number of tests.
For example, if a library has 25 full slots and a sequential slot test is set to run 50 times, the library will

test slots 1-25, then begin at 1 again and test through 25. If you set the same library to run the sequential

slot test 60 times, it will test 1-25, 1-25, then 1-10.
To access the Diagnostics screen, press Diags from the Home screen. The OCP displays the Diagnostics

screen (see

Figure 46

and

Figure 48

).

68

Library operations