4.17

Analyzing the Policy Advisor Results for Hardware Changes

3PAR Policy Advisor User’s Guide

The system is checked for active tuning operations:

---------------------------

Active Tune analysis

---------------------------

No active tunes detected on Target InServ

The virtual volumes are analyzed:

--------------------------------------------------------------------

VV USR Space Analysis (VVs in USR space size order, smallest first)

--------------------------------------------------------------------

A total of 1 Virtual Volumes (VVs) will be analyzed

--Rsvd(MB)---(MB)-- ----PDs--- --Chunklets/PD--
ID Name Prov Type Adm Snp Usr Vsize Nodes RAID SetSz Avail CAvail PDType:KRPM Used Avail Max Min Avg
TotalChunks CPG SNP_CPG CreationPattern
3400 aldvv1 full base 0 0 10240 10240 0 1 2 cage port FC:10 16 32 5 5 5.0
80 --- --- -devtype FC

Fields marked with "---" are not applicable

-----------------------------------------

Non-cpg based VVs meeting tuning criteria

-----------------------------------------

Analyzing possible tune commands

A total of 1 Virtual Volumes (VVs) will be analyzed

Name -----Criteria------ ------SkipReason------- ---------TuneCmd----------

aldvv1 {PD usage=16/32 (50%/threshold 90%) of FC:10} tunealdvv -t r1 -ssz 2 -ha

port -p -devtype FC -f aldvv1

After the analysis, the suggested CLI commands you should run are displayed:

---------------------------

Suggested tune command list

---------------------------

tunealdvv -t r1 -ssz 2 -ha port -p -devtype FC -f aldvv1

Total of 1 tune command to run

For a complete list of options available for the

tunealdvv

command, see the InForm OS

Command Line Interface Reference and InForm CLI Help.