HP XP P9500 Storage User Manual

Page 192

Advertising
background image

Table 37 Command error messages (continued)

Value

Recommended action

Condition

Error

message

Error code

217

Choose an existing CTGID (use
pairvolchk

to display CTGIDs).

CTGID could not be
registered due to being
beyond the max number of

Not enough CT
groups in the RAID

EX_ENOCTG

Use the ‘-f async <CTGID>‘ option

CT groups (0-255 for

of the paircreate command to

XP24000/XP20000 Disk

force the pair into a pre-existing
CTGID.

Array, 0-255 for XP12000
Disk Array/XP10000 Disk
Array, 0-127 for
XP1024/XP128 Disk Array,
0-15 for 7700E)) for an
async volume.

216

Please confirm the serial # of the
volumes by using the pairdisplay

A Continuous Access
Asynchronous or Business
Copy volume is defined in

Extended CT group
across RAIDs

EX_EXTCTG

command to verify that the CT group

the configuration file

is contained completely within one
RAID storage system.

(HORCM_CONF) as a
group that extends across
storage systems.

215

Please confirm whether all CT groups
are already used by mainframe

An available CT group for
OPEN Volume does not exist

No CT groups left
for OPEN Vol use.

EX_ENXCTG

volumes (Cnt Ac-S and Continuous
Access Asynchronous, and BC).

(Continuous Access
Asynchronous or Business
Copy).

214

Please confirm the CTGID using the
pairvolchk

command and/or

The CT group references
within a group do not have
an identical CTGID.

Unmatched CTGID
within the group

EX_ENQCTG

confirm that group references within
the configuration file
(HORCM_CONF) see the same CT
group.

213

Please confirm whether
pair-operation is permitted on the

A device mentioned in the
configuration file does not

Permission denied
with the LDEV

EX_ENPERM

device by using the pairdisplay

have a permission for a
pair-operation.

or raidscan -find verify
command.

212

Please confirm volume size or
number of LUSE volume using the

Size of a volume is
unsuitable between the
remote and local volume.

Unmatched volume
size for pairing

EX_ENQSIZ

‘raidscan -f’ command, and make
sure the volume sizes are identical.

211

Please confirm if the type of storage
system is permitted for a RAID

A storage system (RAID)
mentioned in the

Permission denied
with the RAID

EX_ERPERM

Manager by using the inqraid
-CLI

and raidqry -h commands.

configuration file does not
have a permission for RAID
Manager.

209

Please confirm whether a target
volume is setting to S-VOL disabling

A specified target volume for
S-VOL is denied to become

S-VOL denied due to
be disabling

EX_ES-VOLD

y using inqraid -fl or

S-VOL by the setting of Data
Retention.

raidvchkscan -v gflag
command.

210

Please confirm the microcode version
by using the raidqry -l
command.

The storage system does not
support a function for RAID
Manager.

Micro code not
supported

EX_ENOSUP

208

Please confirm the retention time for
a target volume that is set to Data

A target volume is denied to
be changing due to retention
time via LDEV guarding.

Mode changes
denied due to
retention time

EX_EPRORT

Retention by using raidvchkscan
-v gflag

command.

192 Troubleshooting

Advertising
This manual is related to the following products: