Determining drive status, Removing a hard disk drive – HP Integrity rx4610 Server User Manual

Page 34

Advertising
background image

Chapter 4: Installing Mass Storage Devices

27

from the factory. The procedures in this section describe how to determine drive status, remove a
faulty drive, and install a new drive.

Determining Drive Status

Status LEDs arranged in sets of three over each of the two Hard Disk Bays monitor the status of each
drive.

Table 4-1. SCSI Drive Status LED Descriptions

SCSI drive present

with power on

Green LED

Left

SCSI drive

active

Green LED

Middle

SCSI drive

faulty*

Amber LED

Right


Description and Action

(If Required)

On

Off

Off

Drive is present with
power.

On

Blinking

Off

Drive is present with
power and is being
accessed.

Off

Off

On

Steady amber fault light
indicates drive has a
problem.

On

Off

Slow Blinking

Drive SHOULD NOT be
replaced at this time. A
slowly blinking amber
fault light indicates that a
drive that has just been
replaced is in recovery
mode (drive array being
rebuilt). Power to drive is
on.

Off

Off

Off

There is no drive installed
in the bay.

Removing a Hard Disk Drive

To remove a hard disk drive from the disk bay, complete the following procedure:

1. Look at the amber LEDs above the hard disk bays to determine which drive is bad. See Table

4-1 for information on how to interpret the LEDs.

2. Remove the plastic bezel on the front of the server.

3. Depress the drive carrier latch of the bad drive, and use the handle to pull the assembly toward

you to disengage the drive from the backplane connector.