Expand unit – HP StorageWorks 1510i Modular Smart Array User Manual

Page 65

Advertising
background image

expand unit

Description

Adds a physical drive or drives to the LUN. This enables the specified unit

and all units on the same volume to utilize more disks, effectively allowing

them to increase in size.

NOTE:

Because this command affects the entire array, all LUNs made from the

array are also affected.

Syntax

expand unit <unit> <disk range>

Operands

<unit>

The unit number (0-31) of any one of the LUNs within the target array. Any

LUN in the array can be entered to identify the array; the space is added to

the array and not the LUN.

<diskrange>

A range of disks to be included in the LUN. This range must include the

pre-expansion disks as well as the additional disks to be added. The range

can include a single disk, a series of consecutive disks, or multiple series of

single or consecutive disks. Disks are identified as disk<xyy>, where <x> is

the box number (1-3) and <yy> is the bay number (01-14). For example:
• disk101

• disk101-disk105

• "disk101 disk112-disk202 disk314"

Example
To expand the array containing unit 4:

CLI> expand unit 4 disk204-disk207

The actual new array capacity will be 3000MB.

The array with Unit 4 is being expanded.

Use “show unit 4” to monitor progress.

See also

add unit

bind unit

delete unit

show unit

set unit

accept unit

extend unit

migrate unit

set unit_id

show unit_id

unbind unit

newpage pi

1510i Modular Smart Array Command Line Interface user guide

65