HP StorageWorks 1000 Modular Smart Array User Manual

Page 41

Advertising
background image

Controller Display Messages

41

MSA1000 Controller User Guide

65 CACHE
HARDWARE ENABLED

Informational

The cache hardware had

been temporarily disabled

but is now enabled again.

This may have been due to

insufficient charge on the

batteries that have now

charged up to capacity.

66 CACHE
HARDWARE FAILED
AND DISABLED

Error

The cache memory has

experienced a hardware

failure.

If the failure has occurred

on the

standby

array

controller, then remove the

standby

array controller,

replace the cache modules,

wait 10 seconds, and then

reinsert the array controller

insuring that it is fully

seated in the chassis.

If the failure has occurred

on the

active

array

controller, then wait until

downtime is available.

Power off the MSA1000,

remove the array controller,

replace the cache modules,

and reinsert the array

controller insuring it is fully

seated in the chassis.

Should the issue persist

please contact HP support

67 CACHE
HARDWARE
TEMPORARILY
DISABLED

Informational

The cache memory

hardware has temporarily

been disabled typically

because either the battery

is not charged up or a

capacity expansion

operation is occurring. The

cache will automatically be

enabled once the condition

has been corrected.

Table 3: LCD Message Descriptions

Message

Type

Description

Action

Advertising