HP XP P9500 Storage User Manual

Page 350

Advertising
background image

Table 105 Using a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration (continued)

See:

Description

Target

Maintenance
or failure

No.

maintenance”
(page 352)

“Performing
intermediate

Create a Continuous Access Journal Z copy pair between the primary site
and the remote site, and then change the configuration to a 2DC
configuration (Primary

→ Remote).

Intermediate site
storage system
maintenance

2

site
storage
system
maintenance”
(page 355)

“Performing
remote

Suspend the Continuous Access Journal Z copy pair between the intermediate
site and the remote site, and then change the configuration to a 2DC
configuration (Primary

→ Intermediate).

Remote site storage
system maintenance

3

site
storage
system
maintenance”
(page 358)

“Performing
primary

Reverse the copy direction of the Continuous Access Journal Z copy pair
between the primary site and the intermediate site, and then change the

Primary site host
maintenance

4

site host

configuration to a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration

maintenance”
(page 359)

in which operation is performed from the intermediate site (Intermediate

Primary, and Intermediate

→ Remote).

--

Operation in a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration is not
affected.

Intermediate site host
maintenance

5

--

Operation in a 3DC Cascade (Cnt Ac-J Z x Cnt Ac-J Z) configuration is not
affected.

Remote site host
maintenance

6

“Operating
procedure

Suspend the Continuous Access Journal Z copy pair between the primary
site and the intermediate site, and then change the configuration to a 2DC
configuration (Intermediate

→ Remote).

Primary site storage
system failure (with
information lost from
memory)

Failure

7

during a
primary
site
storage
system
failure
(with
information
lost from
memory)”
(page 362)

“Operating
procedure

Suspend the Continuous Access Journal Z copy pair between the primary
site and the intermediate site, and then change the configuration to a 2DC
configuration (Intermediate

→ Remote).

Primary site storage
system failure (with
no information lost
from memory)

8

during a
primary
site
storage
system
failure
(with no
information
lost from
memory)”
(page 362)

“Operating
procedure

Create a Continuous Access Journal Z copy pair between the primary site
and the remote site, and then change the configuration to a 2DC

Intermediate site
storage system

9

during an

configuration (Primary

→ Remote). During recovery, the Continuous Access

failure (with

intermediate

Journal Z copy pairs must be re-created between the primary site and the
intermediate site, and between the intermediate site and the remote site.

information lost from
memory)

site

350 Maintenance and troubleshooting operations

Advertising