2. HDLM Functions

39

check the IEP item displayed when the

dlnkmgr

command's

view -path

operation

is executed with the

-iem

parameter specified, or the Intermittent Error Path item

specified in the Path List view of the HDLM GUI. If 0 or greater is displayed in the

Intermittent Error Path item, then intermittent error monitoring is being performed.

Table 2-6: When Effects of a User Changing the Intermittent Error Information

User operation

Number of errors

and time passed

since error
monitoring

started

Information

about paths not

subject to
automatic

failback

Changing the intermittent
error monitoring settings

Turning

off

Reset

Reset

#1

Changing the conditions for an

intermittent error while intermittent

error monitoring is being performed

Reset

#2

Inherited

Turning intermittent error

monitoring

on

by executing the

set

operation, (but not changing the
conditions) while intermittent error

monitoring is being performed

Clicking the Apply or OK button in
the HDLM GUI Options window

#3

while intermittent error monitoring

is being performed

Changing the intermittent error

monitoring conditions while

intermittent error monitoring is not
being performed

(Not applicable) (Not

counted.)

Inherited

Changing the automatic

failback settings

Turning

off

Reset

Reset

Changing the path status

Taking the path

Offline(C)

Reset

Reset

Placing the path

Online

while

intermittent error monitoring is not
being performed

(Not applicable) (Not

counted.)