HP XP P9500 Storage User Manual

Page 372

Advertising
background image

intermittent-error-monitoring

If this condition is not satisfied, the KAPL01080-W message will be

output and an error will occur. If this happens, change any of the

following settings: the checking interval for automatic failbacks, the

intermittent error-monitoring interval, or the number of times that the

error is to occur.
When you set the number of times that the error is to occur to 1, the

above condition does not need to be satisfied.
When you changed the error monitor interval during monitoring an

intermittent error, the new setting takes effect immediately. When the

checking interval is shortened and the checking interval after the

change (from the end of the previous path status check) has already

elapsed, the path status check will start immediately.
This setting remains stored in the system, even if you disable the

function by changing the setting of automatic failbacks to off.

Therefore, if you re-enable automatic failbacks and do not change the

interval, path status checks will be executed at the interval already

stored in the system.

-iem { on [-intvl error-monitoring-interval] [-iemnum number-of-
times-error-is-to-occur
] | off }

Enables or disables intermittent error monitoring.
on: Enabled
off: Disabled
Intermittent error monitoring can be set automatic failback is set to on.
The default is off. When you use automatic failback, we recommend that

you set intermittent error monitoring to on to prevent an intermittent

error from reducing I/O performance.
If on is specified, be sure to also specify the intermittent error monitoring

interval and the number of times that the error is to occur. The system

assumes that an intermittent error is occurring if the specified number of

times that the error is to occur is reached during the monitoring interval.

A path that is assumed to have an intermittent error is excluded from

automatic failbacks. Intermittent error monitoring is performed on each

path. Intermittent error monitoring starts when a path is recovered from

an error by performing an automatic failback.
If you omit the intermittent error monitoring interval or the number of

times that the error is to occur, each setting is specified as follows:

¢

When the intermittent error monitoring interval or the number of

times that the error is to occur has not been specified before:
The intermittent error monitoring interval is set to 30 minutes, and

the number of times that the error is to occur is set to 3.

¢

When the intermittent error monitoring interval or the number of

times that the error is to occur has been specified before:
The values specified from the last time are used.

6-20

Command Reference

Hitachi Dynamic Link Manager User Guide (for Linux(R))