HP XP P9500 Storage User Manual

Page 504

Advertising
background image

Message ID

Message Text

Explanation

hh...hh: Host device name (same

as HDevName of view -path)

Action

There could be an error in the

path. See

What To Do for a Path

Error on page 5-3

and restore the

path displayed in the message to

running status.

KAPL08023-I

A path was recovered. PathID =

aa...aa, PathName =

bb...bb.cc...cc.dd...dd.ee...ee,

DNum = ff...ff, HDevName =

gg...gg

Details

aa...aa: Path ID (same as PathID

of view -path) (decimal (base-10)

number)
bb...bb: Host port number (same

as PathName of view -path)

(hexadecimal number)
cc...cc: Bus number (same as

PathName of view -path)

(hexadecimal number)
dd...dd: Target ID (same as

PathName of view -path)

(hexadecimal number)
ee...ee: HLU number (same as

PathName of view -path)

(hexadecimal number)
ff...ff: Device number (same as

DNum of view -path) (decimal

(base-10) number)
gg...gg: Host Dev name (same as

HDevName of view -path)

Action

None.

KAPL08026-E

An error occurred on all the

paths of the LU. PathID =

aa...aa

Details

An error occurred in the last,

remaining path of an LU. (This is

most likely as a result of a

disconnection.)
aa...aa: Path ID (same as PathID

of view -path) (decimal (base-10)

number)

Action

Errors are detected in all the

paths connected to the LUs. See

What To Do for a Path Error on

page 5-3

to make the path shown

in the error message or the paths

connected to the target LU.

KAPL08027-E

A path was excluded from the

items subject to automatic

failback. PathID = aa...aa

Details

A path was excluded from being

subject to automatic failbacks

8-44