HP StorageWorks XP Remote Web Console Software User Manual

Page 71

Advertising
background image

Use the Add RCU pane to register RCUs to the current CU image of the connected MCU. When
you select Add RCU, the Add RCU pane appears (see

Figure 33 (page 71)

).

NOTE:

If four RCUs (maximum number of RCUs you can register) are already registered, you

cannot select Add RCU.

Figure 33 Add RCU pane

RCU S/N: Serial number of RCU being registered. S/N is five digits.

Controller ID: Controller ID of RCU being registered.

Logical Adr. (RCU CU#): CU number of RCU being registered. CU number is 0-1F.

Path Gr.ID: Used to enter the path group ID for using CU Free. To enter the path group ID,
clear the Default check box, and input the value in hexadecimal within the range of 1 to FF.
To use the default ID, select the Default check box.

SSID: SSIDs of RCU being registered. The array uses one SSID for each set of 256 volumes
and four SSIDs per CU image. The SSID is 4-FEFF in hexadecimal.

MCU-RCU Path: Includes:

MCU Port: MCU port number. Only Initiators are listed in the drop-down list. Select the
MCU port from the list.

RCU Port: RCU port number. Select the RCU Target port.

Link Address: Link address from 0 - FD in hexadecimal numbers (serial only). For dynamic
link of remote copy connections, enter destination port address on the ESCD. For static
connections, enter 0.

Option button: Opens the RCU Option pane (

Figure 34 (page 72)

).

Cancel button: Cancels settings made on the Add RCU pane, and closes the pane.

RCU operations

71

Advertising
This manual is related to the following products: