Mezzanine connector definitions, System maintenance switch, System maintenance switch procedures – HP ProLiant BL490c G7 Server-Blade User Manual

Page 8: Clearing the system configuration

Advertising
background image

Component identification 8

Item

Description

13

TPM connector

14

System maintenance switch

15

Processor socket 2

16

Processor socket 1

The symbols

correspond to the symbols located on the interconnect bays. For more information, see the

HP ProLiant BL490c G7 Server Blade Installation Instructions that ship with the server blade.

Mezzanine connector definitions

Item

Connector

Card support

Mezzanine connector 1

PCIe x8

Type I mezzanine card only

Mezzanine connector 2

PCIe x8

Type I or II mezzanine card

System maintenance switch

Position

Function

Default

1*

iLO 3 security override

Off

2

Configuration lock

Off

3

Reserved

Off

4

Reserved

Off

5*

Password disabled

Off

6*

Reset configuration

Off

7

Reserved

Off

8

Reserved

Off

*To access redundant ROM, set S1, S5, and S6 to ON.

System maintenance switch procedures

When you perform troubleshooting steps, this guide may instruct you to perform the following procedures:

Clear the system configuration ("

Clearing the system configuration

" on page

8

).

Access the redundant ROM ("

Accessing the redundant ROM

" on page

9

).

To complete these procedures, you must change physical settings on the system maintenance switch.

Clearing the system configuration

RBSU can be used to restore the factory default configuration. For more information, see "HP ROM-Based
Setup Utility (on page

49

)." If the system is unable to boot into RBSU, use the following steps to clear the

system configuration:

1.

Power down the server blade (on page

11

).

2.

Remove the server blade (on page

12

).

3.

Remove the access panel (on page

13

).

4.

Change position 6 of the system maintenance switch to on.