Viewing current scsi address settings, Setting scsi addresses – HP Surestore 2.15 Tape Library User Manual

Page 60

Advertising
background image

4-10

Library Operation

Specifying SCSI Addresses

Viewing Current SCSI Address Settings

1 2

ADMIN*

PSWD 000 000 000

SCSI IDs

VIEW IDs

To view the current SCSI address settings:

a. Verify that the drive status displays (if not, press

CANCEL

until it does).

b. Press

NEXT

until

ADMIN*

displays, then press

ENTER

.

c. Enter the three-part numerical password (see “Entering the

Administration Menu Password” on page 4-7).

d. Press

NEXT

until

SCSI IDs*

displays, then press

ENTER

.

8.

SET IDs*

displays. Press

NEXT

until

VIEW IDs*

displays, then press

ENTER

.

9.

BUS1 LIB ID#

or

BUS# DRV * ID *

displays. (BUS1 LIB ID # stands

for the current SCSI ID of the robotics controller.
BUS# DRV # ID # is the current SCSI ID setting for the displayed drive
number and its associated BUS#.)

Press

NEXT

or

PREV

to scroll through the current address settings.

a. Press

CANCEL

until the next operation to perform displays, or until the

drive status (library “ready” state) displays.

Setting SCSI Addresses

1 2

ADMIN*

PSWD 000 000 000

SCSI IDs

SET IDs

A SCSI address is required for the robotics controller and each drive. For
more information, see Table 4-2, “Default SCSI Address Setting” on page 4-9,
and the section “Viewing Current SCSI Addresses” on page 4-10.

When setting SCSI addresses, note that:

On bus 1, drive 1 uses one address and the robotics controller uses one
address.

On bus 2, drive 2 uses one address (two-drive libraries only). If the drives
are daisy-chained, the robotics and each drive use one address on the bus.

To change the current SCSI address settings:

1. Verify that the drive status displays (if not, press

CANCEL

until it does).

2. Press

NEXT

until

ADMIN*

displays, then press

ENTER

.