8–6

8.1.6 Replacing a Storage Host Bus Adapter on an EVA4000 array (HP Part

Number FCA2214 DC)

Configuration impact

Changes the WWID of the ports.

Process

1.

Update the presentation of virtual disks on each EVA. Refer to Chapter 5 of the HP StorageWorks

Scalable File Share System Installation and Upgrade Guide for information on presenting virtual

disks.

2.

Reboot the server.

8.1.7 Replacing a Fibre Channel cable (from server to Fibre Channel switch)

Configuration impact

None.

Process

Reboot the server.

8.1.8 Replacing a Fibre Channel switch

Configuration impact

None.

Process

Reboot the servers attached to the switch, but stagger the rebooting so that services are not lost, as follows:

1.

Reboot one server in each server pair attached to the switch.

2.

When the first server in each server pair has rebooted, reboot the second server in each server pair

attached to the switch.

8.1.9 Replacing an EVA4000 controller

Configuration impact

None.

Process

Reboot the servers that use the EVA4000 array.

When you replace a controller on an array, it may happen that the LUNs on the array are not correctly

presented to the controllers. You can check the LUN presentation using the

/usr/opt/hpls/diags/

bin/controller_check.bash

command, and if necessary, reconfigure the LUN presentations. See

Section 9.29 for information on troubleshooting LUN presentation.