Preparing the opening, Warning, Overall cooktop dimensions 3 – GE JP356BMBB User Manual

Page 3: Vertical clearance

Advertising
background image

WARNING –

The electrical power to

the cooktop supply line must be shut off while

connections are being made. Failure to do so

could result in serious injury or death.

A When preparing cooktop opening, make sure

the inside of the cabinet and the cooktop do

not interfere with each other. (See section on

preparing the opening.)

B Remove packaging materials and literature

package from the cooktop before beginning

installation.

Installation Instructions

PRE-INSTALLATION CHECKLIST

C Remove Installation

Instructions from literature

pack and read them

carefully before you begin.

Be sure to place all

literature, Owner’s Manual,

Installations, etc. in a safe

place for future reference.

D Make sure you have all the tools and materials

you need before starting the installation of the

cooktop.

E Your home must provide the adequate

electrical service needed to safely and

properly use your cooktop. (Refer to section on

electrical requirements.)

F When installing your cooktop in your home,

make sure all local codes and ordinances are

followed exactly as stated.

G Make sure the wall coverings, countertop and

cabinets around the cooktop can withstand

heat (up to 200°F) generated by the cooktop.

ON

HOT

Cooktop

Literature

Package

Foam

Packaging

1

The following MINIMUM clearance dimensions

must be maintained.

PREPARING THE OPENING

13" MAX. Depth of unprotected

overhead cabinets

30" MIN.

Clearance from

countertop to

unprotected

overhead

surface

2" MIN. Clearance

from cutout to side

wall on the left of

the unit

15" MIN. Height

from countertop to

nearest cabinet on

either side of unit

1-1/2" MIN.

Clearance from

cutout to side wall

on the right of the

unit

If a 30" clearance between the cooking surface and

overhead combustible materials or metal cabinets

cannot be maintained, a minimum clearance of 24"

is required and the underside of the cabinets above

the cooktop must be protected with not less than

1/4" insulating millboard covered with sheet metal

not less than 0.0122" thick.

2

OVERALL COOKTOP DIMENSIONS

3

VERTICAL CLEARANCE

Allow 5” minimum

vertical clearance

from the cooktop

bottom (or 8-1/4”

minimum depth from

the countertop) to any

combustible surfaces,

such as a cabinet

drawer.

DRAWER

28"

Cooktop

29-3/4"

(29-7/8" SS)

19-1/4"

3-1/4" Front

4-3/16" Rear

at the conduit

location
6-1/4" Rear

on Model PP945

& PP950

21-3/8" (21-1/2" SS)

3

5"

8-1/4"

Advertising