TABLE OF CONTENTS

TECHNICAL DATA

HRV(D) Series .................................................................................................. 3
HRV Series ...................................................................................................... 5
HRV-300D.................................................................................................... ...7

OPERATION............................................................................................................11

Modes Of Operation ........................................................................................11
Optional Remote Controls ................................................................................ 12
Digital Multi-Function Controls w/recirculation.....................................................12
Digital Multi-Function Controls .........................................................................13

INSTALLATION........................................................................................................14

Mounting the Unit .......................................................................................... 14
Location & Ducting .......................................................................................... 15
Examples ....................................................................................................... 18
Air Flow Balancing ......................................................................................... 22

MAINTENANCE ..................................................................................................... 24

TROUBLESHOOTING............................................................................................... 25

ELECTRICAL CONNECTIONS ................................................................................. 26

Sizing (Example) for maximum airflow normally required.

HRVs are typically sized to ventilate the whole house at a minimum of 0.35 air changes per
hour. To calculate, simply take the square footage of the house (including basement) and multi-
ply by the height of the ceiling to get cubic volume. Then, divide by 60 and multiply by 0.35.
Example:

SQFT of House

1100

Basement

1100

Total SQFT

2200

Height of ceiling

x 8

Cubic volume

17600

/ 60

Maximum airflow required (CFM)

293

x 0.35

103

* Always consult your local code for sizing requirements in your area.

Room classification

Number of rooms

CFM (L/s)

CFM Required

Master bedroom

x 20 cfm (10 l/s)

=

Basement

yes or no

=

Bedrooms

x 10 cfm (5 l/s)

=

Living room

x 10 cfm (5 l/s)

=

Others

x 10 cfm (5 l/s)

=

Kitchen

x 10 cfm (5 l/s)

=

Bathroom

x 10 cfm (5 l/s)

=

Laundry room

x 10 cfm (5 l/s)

=

Utility room

x 10 cfm (5 l/s)

=

Total Ventilation Requirements (add last column )

=

if yes add 20 cfm / 10 l/s

if no = 0

1 cfm = 0.47189 l/s

1 l/s = 3.6 m

3

/hr

Alternate Method

***Illustrations &

images in this

manual may not be

exactly like unit

purchase, these

illustrations &

images are for

examples only.***