Warning, Installation instructions, Exhaust system check list – GE GTDP740EDWW User Manual

Page 5: Parts available from local service organizations, Exhaust connection

Advertising
background image

Installation Instructions



SEALING OF JOINTS

<

All joints should be tight to avoid leaks. The male end of each
section of duct must point away from the dryer.

<

The duct shall not be assembled with screws or other
fastening means that extend into the duct and catch lint.

<

Duct joints can be made air and moisture-tight by wrapping
the overlapped joints with duct tape.

<

Horizontal runs should slope down toward the outdoors
1/4 inch per foot.

INSULATION

Duct work that runs through an unheated area or is near air
conditioning should be insulated to reduce

condensation and

lint build-up.

EXHAUST SYSTEM CHECK LIST

HOOD OR WALL CAP

< Terminate in a manner to prevent back drafts or entry of birds

or other wildlife.

< Termination should present minimal resistance to the exhaust

air flow and should require little or no maintenace to prevent clogging

< Never install a screen in or over the exhaust duct. This could

cause lint build up.

< Wall caps must be installed at least 12 in. above ground level

or any other obstruction with the opening pointed down.

SEPARATION OF TURNS

For best performance, separate all turns by at least 4 ft. of straight
duct, including distance between last turn and exhaust hood.

TURNS OTHER THAN 90º

< One turn of 45º or less may be ignored.
< Two 45º turns should be treated as one 90º turn.
< Each turn over 45º should be treated as one 90º turn.

PARTS AVAILABLE FROM LOCAL SERVICE
ORGANIZATIONS

< Rigid Metal Duct Components

WX8X63

4

ʺ x 1ʹ Duct

WX8X64

4

ʺ x 2ʹ Duct

WX8X51

4

ʺ Elbow

WX8X59

4

ʺ Aluminum Hood

< Flexible Metal Duct Components

WX8X58

4

ʺ Clamps (2)

WX8X59

4

ʺ Aluminum Hood

WX08X10077

6

ʹ UL-Listed, Flexible Metal (Semi-Rigid)

Duct, 2 Clamps, 2 Close Elbows

WE1M454 Cover rear exhaust opening

For every extra 90°elbow, reduce the allowable vent system
length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to the
chart.
The total vent system length includes all the straight portions
and elbows of the system (transition duct included).

4

EXHAUST CONNECTION

There are multiple installation options.

Select the most appropriate method for your
installation situation.

TO REDUCE THE RISK OF FIRE OR
PERSONAL INJURY:

+# $#")"%#$(%#$$ $ %$ "#
+# ),"$ " #$")"$"#$ %$$
 $$")"$ $ (%#$ $%#$#$
 "'$$#$"%$ # %“Connecting the
Dryer to House Vent”
! $#%
+ (%#$$ )$(%#$#&$
'$$"'#! " #! %
$%%$$ %"$! $$"*"
+ %#!#$&$
+ %#$ &$
+ " &$
+ &"$"$$(%#$$   %$'$
$(%#$#)#$ $  "#$
 %"$! $$"*"
+  $%#%$ "$#!$(%#$$
$ "%$#%%$$"$! $$
"*"
+ &"#$#" " &"$(%#$%$#'
%#$$ %%$"$! $$"*"
+  $##%$' "'$)#$"#$$($$
$%$##$"#%%$$"$
! $$"*"
+

  $ #$"%$  "(%#$"

+" &## "#!$  $(%#$
#)#$#!)$$%"# $# (%#$#)#$#
#!$$#$ )"
+ %"$   '$##$"%$ #"#%$$ ""

Fire Hazard

WARNING

Advertising
This manual is related to the following products: