Hood exhaust, Installation instructions, Outside top exhaust (example only) – GE PSA9240DFWW User Manual

Page 4: Outside back exhaust (example only)

Advertising
background image

4

HOOD EXHAUST

NOTE: 5HDGWKHVHQH[WWZRSDJHVRQO\LI\RXSODQWRYHQW\RXUH[KDXVWWRWKHRXWVLGH
,I\RXSODQWRUHFLUFXODWHWKHDLUEDFNLQWRWKHURRPSURFHHGWRSDJH

OUTSIDE TOP EXHAUST (EXAMPLE ONLY)

EQUIVALENT

NUMBER

EQUIVALENT

DUCT PIECES

LENGTH

x

USED

=

LENGTH

Roof Cap

24 Ft.

x

(1)

=

24 Ft.

12 Ft. Straight Duct

12 Ft.

x

(1)

=

12 Ft.

(6s Round)

Rectangular-to-Round

5

Ft.

x (1)

= 5

Ft.

Transition

Adaptor*

Equivalent lengths of duct pieces are based on actual tests and

reflect requirements for good venting performance with any vent hood.

Total Length

=

41 Ft.

* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will

have to be cut to fit, using the tin snips, in order to allow free movement of the damper.

The following chart describes an example of one possible

ductwork installation.

Installation Instructions

The following chart describes an example of one possible

ductwork installation.

NOTE: For back exhaust, care should be taken to align exhaust with space between studs, or wall should be prepared

at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.

OUTSIDE BACK EXHAUST (EXAMPLE ONLY)

EQUIVALENT

NUMBER

EQUIVALENT

DUCT PIECES

LENGTH*

x

USED

=

LENGTH

Wall Cap

40 Ft.

x

(1)

=

40 Ft.

3 Ft. Straight Duct

3 Ft.

x

(1)

=

3 Ft.

(3

1

ø

4

s x 10s Rectangular)

90°

Elbow

10

Ft.

x (2)

= 20

Ft.

Equivalent lengths of duct pieces are based on actual tests and

reflect requirements for good venting performance with any vent hood.

Total Length

=

63 Ft.