Technical data, This range is supplied set for natural gas, Dimensions – Aga Ranges LEGACY 36 F104650-01 User Manual

Page 14: Connections

Advertising
background image

SERVICING - WARNING

Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.

14

Technical Data

This range is supplied set for Natural gas.

A conversion kit from NG to LP gas is included.

INSTALLER: Please leave these instructions with the User.

DATA BADGE LOCATION:

Under the Main oven. Remove the plinth by pulling forward (it is held in

place by magnetic catches) and pull forward on the sheet metal tag under the center of the oven to swing
out the badge plate.

Country of Destination: USA/Canada

Gas

Electric

Natural Gas 4.0” W.C

(10 mbar)

240V 60Hz

Propane

10.0” W.C (

25 mbar)

(See appliance data badge for test pressures)

Dimensions

Overall height (splash not fi tted)

minimum 35

3

/

8

(89.8 cm)

maximum

36

7

/

16

” (

92.5 cm)

Overall width

35

1

/

2

(90cm)

See ‘Positioning the Range’

Overall depth with spacer

28

3

/

4

” (73cm)

Space for fi xing

See ‘Positioning the Range’

Minimum space above cooktop

30” (76cm)

Connections

Gas :

Electric:

1

/

2

” NPT at rear right-hand side

240 V 60 Hz

Advertising