Installation Instructions

67250:,1'2:5(48,5(0(176

A storm window frame will not allow the air

conditioner to tilt toward the outside, and will keep it

from draining properly.

To adjust for this, attach a piece of wood to the sill.
:22'3,(&(6
:,'7+µ
/(1*7+
Long enough to fit inside the window

frame.
7+,&.1(66 To determine the thickness, place a

piece of wood on the sill to make it 1/2” higher than

the top of the storm window frame or the vinyl

frame.
Attach securely with nails or screws provided by the

installer.

:,1'2:5(48,5(0(176

These instructions are for a standard double-hung

window. You will need to modify them for other types

of windows.

• The air conditioner can be installed without the

accordion panels if needed to fit in a narrow

window. See the window opening dimensions.

• All supporting parts must be secured

to firm wood, masonry or metal.

• The electrical outlet must be within reach of the

power cord.

1

35(3$5(7+($,5&21',7,21(5

Hold the accordion panel in one hand and

gently pull back to free the open end.

Slide the free end of the accordion panel into

the side panel rails. Slide the panel down. Be

sure to leave enough space to slip the top

and bottom of the frame into the rails on the

cabinet.
NOTE: There is a right and a left accordion

panel. Be sure to use the proper panel for each

side.

Slide the left and right accordion panels into

the top and bottom mounting rails.



A

C

Top left

Top right



1/2

higher

than storm

window

frame

Storm window

frame

Wood

Sill

1/2

µ

higher

than vinyl frame

(on some windows)

Vinyl frame

Top mounting rail

B

9

15 ½” min.

22” to 36”

(With accordion panels)

Bottom mounting rail