Warning, Installation instructions, Caution – GE DCVH480EKWW User Manual

Page 21: Side venting

Advertising
background image

21

WARNING –

BEFORE

PERFORMING THIS EXHAUST INSTALLATION, BE

SURE TO DISCONNECT THE DRYER FROM ITS

ELECTRICAL SUPPLY. PROTECT YOUR HANDS

AND ARMS FROM SHARP EDGES WHEN

WORKING INSIDE THE CABINET. BE SURE TO

WEAR GLOVES.

Installation Instructions

SIDE VENTING:

Dryer Exhaust to side of cabinet

Detach and remove the bottom, right or left side

knockout as desired. Remove the screw from the

rear of the casing and save. Pull the duct out of

the dryer.

Remove

screw and

save

Remove desired

knockout (one only)

Fixing hole

Cut the duct as shown and keep portion A.

ADDING A NEW DUCT

Reconnect the cut portion (A) of the duct to the

blower housing. Make sure that the screw holes

in the duct and ramp base are aligned. Use the

screw saved previously to secure the duct in place

through the ramp on the appliance base.

ADDING ELBOW AND DUCT FOR EXHAUST

TO LEFT OR RIGHT SIDE OF CABINET

Tape the connection between the duct and elbow.

Insert the duct with elbow through the rear

opening and connect to the internal duct.

CAUTION:

Be sure not to pull or

damage the electrical wires inside the dryer when

inserting the duct. A slight interference may

occur between the exhaust and the wire

components.

Portion “A”

Left side

exhaust

Fixing hole

Apply duct tape as

shown on the joint

between the dryer

internal duct and

the elbow, and also

the joint between the

elbow and the side duct.

CAUTION:

Internal duct joints must be

secured with tape; otherwise, they may separate

and cause a safety hazard.

Duct tape

A

4.9” (125 mm)

Right

Left

Bottom

Tab

Advertising