Figure 2. Fryer Model SLG40 Site Installation Requirements

CODE REQUIREMENTS

CODE REQUIREMENTS

CODE REQUIREMENTS

CODE REQUIREMENTS

CODE REQUIREMENTS

(Continued)

e. Install this fryer on a non-combustible floor

with its back and sides at least 6” away from
any combustible wall, as shown in Figure 2.

WARNING

Install this fryer under a ventilation
hood that conducts combustion pro-
ducts outside the building. Venting
must comply with ANSI/NFPA 96
(latest edition).

f. Install this fryer in a location where adequate

combustion and ventilation air is available.
Keep the area directly in front of the fryer open
for adequate air flow to the burners. DO
NOT
obstruct the flow of combustion and
ventilation air.

g. Keep the fryer area free and clear from

combustibles and debris.

h. Attach a restraining device to each fryer, to

prevent the unit from tipping, which could
cause splashing of hot liquid .

From the top of the flue on
the fryer, allow a minimum
of at least 10 inches verti-
cal clearance beneath a
ventilating hood.