Section 4, Configuration, 1 jumpers – Atmel Evaluation Board AT91SAM9XE-EK User Manual

Page 20: Configuration -1

Advertising
background image

AT91SAM9XE-EK Evaluation Board User Guide

4-1

6311A–ATARM–04-Feb-08

Section 4

Configuration

4.1

Jumpers

Notes: 1.

These jumpers are provided for power consumption measurement. By default, they are
closed. To use this feature, the user has to open the strap and insert an ammeter.

Table 4-1. Jumpers Configuration

Designation

Default Setting

Feature

J2

Closed

3.3V Jumper

(1)

J3

Closed

Forces power on.

To use the software shutdown control, J3 must be opened. 3V
battery backup must be present.

J6

Closed

VDDPLL Jumper

(1)

J7

2-3

Erase/Normal operation mode

1-2: Erase entire flash chip

2-3 or open: Normal operating mode

J9

2 - 3

Slow Clock OSCSEL

1-2: Internal RC Oscillator

2-3: External Crystal Oscillator

J10

Closed

VDDBU Jumper

(1)

J12

Closed

VDDCORE Jumper

(1)

J15

Closed

Enables Ethernet Auto MDIX control

J32

Closed

Enables the use of the embedded NANDFLASH device (MN6xx)

J33

Closed

Enables the use of the embedded DATAFLASH device (MN9)