Connecting the external time signal – Acroprint ES900 User Manual

Page 56

Advertising
background image

56

54

54

1

Unlock the key and remove the cover.

2

Insert wires into two right terminals

for external time signal, and tighten

both screws.

Connecting the External Time Signal

CAUTION: Be sure to pull out AC cord from AC outlet before connecting wires of the

External Time Signal. Improper connection may cause a malfunction of the unit.

Also refer to "Attaching the Wire Clamp" to secure wires with the wire clamp.

If external signal(s) are required, the addition of a relay (not supplied) will be necessary.

Please consult your local electrician.

When a signal is activated the internal contacts close completing the circuit. These internal

contacts are "dry" and supply no voltage. Voltage applied to these contacts must not exceed

30 volts. An external relay must be used to activate signaling devices.

Recommended Relays: (Or similar line voltage switching relays)

Available at W. W. Grainger

HoneyWell

#RA89A1074

Grainger #2E866

Dayton

#809A-189

Grainger #2E553

Connections shown for Dayton 2E553. Add jumper from terminals 1 to 3.