Valving valve stacks – Penske Racing Shocks 8900 Series User Manual

Page 20

Advertising
background image

20

Part #

VS-AA

AA

.004

.004

.004

.004

Constant

VS-AAP

AA+

.004

.004

.006

.006

Constant

VS-AM

A-

.006

.006

.004

.004

Constant

VS-A

A

.006

.006

.006

.006

Constant

VS-AP

A+

.006

.006

.008

.008

Constant

VS-BM

B-

.008

.008

.006

.006

Constant

VS-B

B

.008

.008

.008

.008

Constant

VS-BP

B+

.008

.008

.010

.010

Constant

VS-CM

C-

.010

.010

.008

.008

Constant

VS-C

C

.010

.010

.010

.010

Constant

VS-CP

C+

.010

.010

.012

.012

Constant

VS-DM

D-

.012

.012

.010

.010

Constant

VS-D

D

.012

.012

.012

.012

Constant

VS-DP

D+

.012

.012

.015

.015

Constant

VS-EM

E-

.015

.015

.012

.012

Constant

VS-E

E

.015

.015

.015

.015

Constant

VS-EP

E+

.015

.015

.020

.020

Constant

VS-FM

F-

.020

.020

.015

.015

Constant

VS-F

F

.020

.020

.020

.020

Constant

1.350 O.D.

1.200 O.D.

1.050 O.D.

.900 O.D.

.750 X .020

Constant

Compression Valve Stack

Rebound Valve Stack

Constant

When refering to shock valving, (example: A/B), (A) refers to the compression valve stack and (B) refers
to the rebound valve stack.

Valving

Valve Stacks

Standard

Digressive

Valve

Stack

Advertising