Connecting a maintenance terminal to the d3r, Connecting a maintenance terminal to the scu, Figure 11 – ADC DL3XR-FCA100 User Manual

Page 28: Figure 11 on, D3rcam c

Advertising
background image

Setting Up System Options

LTPS-UM-8013-03

20

August 30, 2002

D3LX CO and RMT Modules

9600 baud

No parity

8 data bits

1 stop bit

Hardware flow control to OFF

Figure 11.

Connecting a Maintenance Terminal to the SCU

5

At the maintenance terminal, press

. The Enter User Name field appears.

C

ONNECTING

A

M

AINTENANCE

T

ERMINAL

TO

THE

D3RCAM C

RAFT

P

ORT

1

Locate the D3RCAM in the remote cabinet. The D3RCAM craft port is located on the front of the D3RCAM.

2

Select the cable for use between the craft port and the maintenance terminal with a DB-9 (male) connector at
one end and a maintenance terminal connector at the other end.

3

Connect one end of the interface cable to the maintenance terminal and the other end to the D3RCAM craft
port as shown in

Figure 12

.

4

Start a terminal emulation program such as Procomm that emulates a VT100 terminal.

The default port configuration for the SCU craft port is CRAFT. Ports 2 and 3 must be configured
for CRAFT before the craft interface may be accessed via these ports.

Craft port

Maintenance

terminal

Serial

COM port

Interface cable

LEC

ENTER