4. WATER RUNS CONTINUOUSLY INTO THE WASHER-EXTRACTOR

CFD20S

1

Turn the main

power to the
machine off.

Does the water

shut off?

2

YES

Clean the valve or
install a repair kit inside
the valve if available. If
a repair kit isn’t
available, replace the
entire valve.

NO

NO

Is there voltage (220 Volts)

between the two wires of the

solenoid on the water valve

that is staying on?

For example, if the 1-5 (hot fill

on X18-75) is staying on, is

there voltage (220 Volts)

between the common (red) and

neutral (blue) wires of the

solenoid?

Is the

main board

(water) harness

connected correctly

as shown on the wiring

schematic and is it intact?

Note: Make sure there are

no wires loose, shorted

or disconnected

from the main

board (water)

harness.

Repair or replace the
main board (water)
harness as needed.

Check the microprocessor
display to make sure that
the microprocessor isn’t
calling for the water
valve to turn on when it
shouldn’t be. If it is, turn
off the power to the machine
for at least 20 seconds and
then turn the power back
on. Make sure that the
display reads “CYCLE 00.”

If the microprocessor is
still calling for the water
valve to turn on when it
shouldn’t be, assuming
that all checks were done
correctly, replace the
main board or contact
Alliance Laundry Systems’
customer service
department to verify that
all checks have been done
correctly.










NOTE: This information applies to the three main fill valves as well as the three supply valves. The first task in this
process is to determine which valve is staying on. This may be done by individually shutting off the water supply to
each valve. Find the location where the water is flushing into the machine and follow the hose back to the solenoid
Once the valve has been identified, proceed as follows:

NO

YES

YES