Test configuration accessories

Power meter and power sensors
E4418A power meter and 8480 series power sensors

Required for use with test port power flatness

correction feature.

Bias supply
6626A precision DC power supply

For connection to 851XA test set bias input, also

order 14852A.

14852A bias interconnect cable

Bias networks
For supplying DC bias externally from the test
set. Standard S-parameter test sets include bias
networks.

11590B bias network
Frequency options
11590B-101 100 MHz - 12.4 GHz with Type-N

connectors (0.5A maximum current)

11590B-001 100 MHz - 18 GHz with 7mm

connectors (0.5A maximum current)

11612A bias network with 3.5 mm connectors
11612A-001 2 amps maximum current (400 MHz -

26.5 GHz)

11612B-002 0.5 amps maximum current (45 MHz -

26.5 GHz)

11612B bias network (45 MHz to 50 GHz) with
2.4 mm connectors (0.5A maximum current)

Amplifier
8349B microwave amplifier
(2 - 20 GHz) May be used
to increase input power level to S-parameter test
sets and increase system dynamic range.
8349B-001 Recommended (rear panel in/out

installed) for use in racked configurations

8349B-UN1 Standard configuration (front panel

in/out)

System rack
85043C system rack kit

132 cm (52 in.) high x 60 cm (23.6 in.) wide x

90.5 cm (35.6 in.) deep. Supplied with anti-static
mat (part number 85043-80013), support rails,
rack mounting kits (Option 913), and power dis-
tribution. Includes two 10833A GPIB cables for
connecting system peripherals to 8510C.

85043C-115 110/120 V line operation
85043C-230 220/240 V line operation

System software
Compatible with a PC, running BASIC Rev 2.1
(85161B) or Windows (95/98/2000 ME/NT).
Comes in 3.5-inch disk media.
85161B measurement automation software
85070D materials measurement software/probe kit

(PC version)

85071D materials measurement software

(PC version)

Peripherals
Hardcopy results may be output directly to a
printer or plotter over the system bus (GPIB com-
patible) or serial output ports (RS-232-C) without
the need of an external computer. Measurement
data, calibration sets and kits, and instrument
states may be stored on disk using either the built-
in disk drive or an external disk drive. GPIB

cables must be ordered for each peripheral. Two

serial interface (RS-232-C) cables are included
with 8510C.

Graphics printers
HP C2678A DeskJet 1120C Color Printer
HP C2679A DeskJet 1120Cse Color Printer
HP C2680A DeskJet 1120Cxi Color Printer
HP C5876A DeskJet 890Cxi Color Printer
HP C5877A DeskJet 890Cse Color Printer
HP C3941A LaserJet 5L Printer
HP C3150A LaserJet 5P Printer

GPIB cables
• 10833A 1-Meter GPIB cable
• 10833B 2-Meter GPIB cable
• 10833D 0.5-Meter GPIB cable