System components – Agilent Technologies 8510C User Manual

Page 5

Advertising
background image

5

System components

For flexibility in specifying a solution that meets
your exact needs, a system can be ordered as sepa-
rate line items. A complete system includes the
Agilent 8510C network analyzer, a test set, compat-
ible source, and measurement accessories.

All major system components (network analyzer,
test sets, and sources) include one-year on-site
service.

8510C ATO options
8510C-008 Pulsed-RF capability requiring 85110A

or 85110L S-parameter test set

8510C-010 Add time domain

Rack flange kits
8510C-908 Rack flange kit, front handles detached
8510C-913 Rack flange kit, front handles attached

Additional documentation
8510C-910 Extra operating and service manual

set

8510C-916 Extra operating and programming

manual set

Extended service options are available.

Test sets (Choose one)
8514B S-parameter test set (45 MHz to 20 GHz)

With rugged 3.5 mm connector test ports

8515A S-parameter test set (45 MHz to 26.5 GHz)

With rugged 3.5 mm connector test ports

8517B S-parameter test set (45 MHz to 50 GHz)

With rugged 2.4 mm connector test ports

85110A pulsed-RF S-parameter test set (2 to 20 GHz)

For use with 8510C Option 008. Includes rugged
3.5 mm connector test ports and four built-in
step attenuators to independently set power
level to all four downconverter channels.
Requires 8360 series synthesized sources for
complete operation (83622B and 83623L).

85110L pulsed-RF S-parameter test set (45 MHz to

2 GHz)
For use with 8510C Option 008. Includes rugged
7 mm connector test ports and four built-in step
attenuators to independently set power level to
all four downconverter channels. Requires two
8360 series synthesized sources for complete
operation (83620B-H80, two each).

8511A frequency converter (45 MHz to 26.5 GHz)

3.5 mm connector ports

8511B frequency converter (45 MHz to 50 GHz)

2.4 mm connector ports

Note: Agilent 8511A/B require external, customer-
furnished couplers, or signal separating devices to
provide complete test set capability. A source with
front panel RF power output may be more suitable
for 8511-based applications.

Test set options

Option

Description

8514B

8515A

8517B

85110A

85110L

8511A/B

STD

No IF switching

X

X

001

Add IF switching for multiple test set operation

X

X

X

X

X

X

002

Delete step attenuators and bias tees

X

X

X

003

High forward dynamic range configuration

X

(degrades reverse transmission dynamic range)

003

Add attenuators and bias tees

X

X

999

Standard input power

X

004

High power configuration (moves port 2

attenuator in front of b2 sampler)

X

004

Add attenuators and bias tees

X

027

High source power

X

908

Add rack flange kit

X

X

913

Add rack flange and handles kit

X

X

X

X

910

Extra operating and service manual

X

X

X

Advertising