Advantus 75705 User Manual

Page 7

Advertising
background image

Specifications

Capacity:

Over Capacity Annunciation:

5 lb x 0.1 oz

103% of Full Scale Capacity


Construction:

Main Power Source:

Housing:

Black ABS

6-AA size alkaline batteries

Sub-Platform

:

Metal

Platter:

Black ABS

Optional Power Source:

Feet:

Non-skid Hard Rubber

AC Adapter, 9 VDC, 100 mA


Display:

Auto Power Off Period:

4 Character, 7-Segment LCD

Fixed at two minutes

7

Annunciators

Weight:

Keypad:

Net Weight:

2.0 lb (0.9 kg)

4-key Tactile Dome Type

Shipping Weight:

2.5 lb (1.1 kg)

Calibration


Your 75705 scale is ready to use right out of the box. There is no need to calibrate the scale unless you
feel that the scale has become inaccurate. It is a good idea to check the calibration of your scale from
time to time with a precision test weight. Advantus Corporation recommends that you perform a new
calibration on your digital scale at least once a year. The 75705 must be calibrated with a 5 pound
precision test weight.

To calibrate the scale:

1. Remove all items from the platter and turn the scale OFF. Press and hold the SAMPLE key while

turning the scale back ON.


2. The scale shows “CAL” briefly then “ZERO”.

3. Press

the

ZERO

key. The scale then shows “ADD”.

4. Place the 5 pound test weight on the platter and wait for scale to show “SAVE”.

5. Press

the

MODE

key to save the 5 pound calibration value.

6. Once the 5 pound calibration value has been saved, the scale shows an “END” message.

7. You must now turn the scale OFF. Then turn it back ON without pressing any other keys. Your

5005-2 is now calibrated and ready for use.

MESSAGE

MEANING / POSSIBLE SOLUTION

Shows “Err”
Continuously

The scale is unstable. Make sure you are not violating one of the “Caution” items.
Otherwise, the scale may require service.

Shows “Add”
Continuously

The scale is not detecting weight internally. Possible damage to the load cell. Scale
requires service.

Possible Calibration Error Messages