AVE MV DR4000 User Manual

Page 11

Advertising
background image

9

2.3

ALARM

In/Out

ALARM1 IN

ALARM4 IN

ALARM2 IN

ALARM3 IN

ALARM OUT

RECORD IN

GROUND

DISK FULL

ALARM RESET

1

2

3

4

5

6

7

8

9

THIS FIGURE IS LOOKED FROM THE REAR VIEW

1. GND:

Ground Contact.

2. ALARM OUT (OUTPUT): This is a common alarm output trigger. Connect this to external

devices such as buzzers or lights. Switches Low (GND) (

5V

0V(Active)

)

3.

DISK FULL (OUTPUT): This is a disk full output trigger. Connect this to external devices such

as buzzers or lights. Switches Low (GND) (

5V

0V(Active)

)

4. ALARM

RESET

(INPUT):

This pin connects to an alarm-clear device for clearing an alarm. Use

a Normally Open switch to GND. (

5V

0V(Active)

)

5. RECORD IN (INPUT): This pin connects to a record trigger device for starting a record.

Negative Trigger. (

5V

0V(Active)

)

6.

ALARM4 IN (INPUT): This is an alarm input (for CH 4 ), which can be programmed in the menu

system to Normally Open or Normally Closed operation.

7.

ALARM3 IN (INPUT): same as the above, for CH 3

8.

ALARM2 IN (INPUT): same as the above, for CH 2

9.

ALARM1 IN (INPUT): same as the above, for CH 1

Advertising