3

Names

Operation Type

Header

Command Data

CRC

Action

Type

Setting Code

M1-D

Set

NORMAL

BE EF

03

06 00

3E D9

01 00

20 20

00 00

ENHANCED

BE EF

03

06 00

AE D8

01 00

20 20

01 00

Get

BE EF

03

06 00

0D D9

02 00

20 20

00 00

RGB 1

Set

SYNC ON G OFF

BE EF

03

06 00

5E D7

01 00

10 20

02 00

SYNC ON G ON

BE EF

03

06 00

CE D6

01 00

10 20

03 00

Get

BE EF

03

06 00

0D D6

02 00

10 20

00 00

RGB 2

Set

SYNC ON G OFF

BE EF

03

06 00

A2 D6

01 00

11 20

02 00

SYNC ON G ON

BE EF

03

06 00

32 D7

01 00

11 20

03 00

Get

BE EF

03

06 00

F1 D7

02 00

11 20

00 00

FRAME LOCK

Set

TURN OFF

BE EF

03

06 00

CB D6

01 00

14 30

00 00

TURN ON

BE EF

03

06 00

5B D7

01 00

14 30

01 00

Get

BE EF

03

06 00

F8 D6

02 00

14 30

00 00

KEYSTONE V

Get

BE EF

03

06 00

B9 D3

02 00

07 20

00 00

Increment

BE EF

03

06 00

DF D3

04 00

07 20

00 00

Decrement

BE EF

03

06 00

0E D2

05 00

07 20

00 00

KEYSTONE V Reset

Execute

BE EF

03

06 00

08 D0

06 00

0C 70

00 00

KEYSTONE H

Get

BE EF

03

06 00

E9 D0

02 00

0B 20

00 00

Increment

BE EF

03

06 00

8F D0

04 00

0B 20

00 00

Decrement

BE EF

03

06 00

5E D1

05 00

0B 20

00 00

KEYSTONE H Reset

Execute

BE EF

03

06 00

98 D8

06 00

20 70

00 00

ACTIVE IRIS

Set

TURN OFF

BE EF

03

06 00

0B 22

01 00

04 33

00 00

THEATER

BE EF

03

06 00

CB SF

01 00

04 33

10 00

PRESENTATION

BE EF

03

06 00

5B 2E

01 00

04 33

11 00

Get

BE EF

03

06 00

38 22

02 00

04 33

00 00

WHISPER

Set

NORMAL

BE EF

03

06 00

3B 23

01 00

00 33

00 00

WHISPER

BE EF

03

06 00

AB 22

01 00

00 33

01 00

Get

BE EF

03

06 00

08 23

02 00

00 33

00 00

MIRROR

Set

NORMAL

BE EF

03

06 00

C7 D2

01 00

01 30

00 00

H:INVERT

BE EF

03

06 00

57 D3

01 00

01 30

01 00

V:INVERT

BE EF

03

06 00

A7 D3

01 00

01 30

02 00

H&V:INVERT

BE EF

03

06 00

37 D2

01 00

01 30

03 00

Get

BE EF

03

06 00

F4 D2

02 00

01 30

00 00

VOLUME-RGB1

Get

BE EF

03

06 00

CD CC

02 00

60 20

00 00

Increment

BE EF

03

06 00

AB CC

04 00

60 20

00 00

Decrement

BE EF

03

06 00

7A CD

05 00

60 20

00 00

VOLUME-RGB2

Get

BE EF

03

06 00

FD CD

02 00

64 20

00 00

Increment

BE EF

03

06 00

9B CD

04 00

64 20

00 00

Decrement

BE EF

03

06 00

4A CC

05 00

64 20

00 00

VOLUME-M1-D

Get

BE EF

03

06 00

89 CC

02 00

63 20

00 00

Increment

BE EF

03

06 00

EF CC

04 00

63 20

00 00

Decrement

BE EF

03

06 00

3E CD

05 00

63 20

00 00

VOLUME-Video

Get

BE EF

03

06 00

31 CD

02 00

61 20

00 00

Increment

BE EF

03

06 00

57 CD

04 00

61 20

00 00

Decrement

BE EF

03

06 00

86 CC

05 00

61 20

00 00

VOLUME-S-Video

Get

BE EF

03

06 00

75 CD

02 00

62 20

00 00

Increment

BE EF

03

06 00

13 CD

04 00

62 20

00 00

Decrement

BE EF

03

06 00

C2 CC

05 00

62 20

00 00

RS-232C Communication (continued)