Rs-232c communication, Connecting the cable, Communications setting – AB Soft CP-X605 User Manual

Page 7

Advertising
background image

7

RS-232C Communication

RS-232C Communication

6 7 8 9



2 3

4 5

6 7 8 9



2 3

4 5

CONTROL port

RS-232C cable (Cross)

RS-232C port

of the projector

of the computer

- ()

() CD

RD (2)

(2) RD

TD (3)

(3) TD

- (4)

(4) DTR

GND (5)

(5) GND

- (6)

(6) DSR

RTS (7)

(7) RTS

CTS (8)

(8) DTS

- (9)

(9) RI

Connecting the cable

.

Turn off the projector and the computer.

2.

Connect the CONTROL port of the projector with a RS-232C port of

the computer by a RS-232C cable (cross). Use the cable that fulfills the

specification shown in the previous page.

3.

Turn the computer on, and after the computer has started up turn the

projector on.

Communications setting

9200bps, 8N
1. Protocol

Consist of header (7 bytes) + command data (6 bytes).
2. Header

BE + EF + 03 + 06 + 00 + CRC_low + CRC_high

CRC_low : Lower byte of CRC flag for command data

CRC_high : Upper byte of CRC flag for command data
3. Command data

Command data chart

byte_0

byte_

byte_2

byte_3

byte_4

byte_5

Action

Type

Setting code

low

high

low

high

low

high

Action (byte_0 - )

Action

Classification

Content



SET

Change setting to desired value.

2

GET

Read projector internal setup value.

4

INCREMENT

Increment setup value by .

5

DECREMENT Decrement setup value by .

6

EXECUTE

Run a command.

Advertising