Teejet spray tip calibration – Ag Spray Equipment RM55 User Manual

Page 6

Advertising
background image

6

TEEJET SPRAY TIP CALIBRATION

BA4DSQ
All standard booms come w/ 8003VP poly tips.
The 4 Row booms have 9 nozzles.

Formula:

Example:

Take the GPM that you figured & look down the GPM chart to figure what pressure you need to run at
that desired speed.

*NOTE: If spraying liquid nitrogen you will need to multiply the conversion factor w/ the gpa, mph, &
nozzle spacing.

Conversion Factor:

Example:

GPM

=

GPA x MPH x Nozzle Spacing.

5940

20GPA x 4MPH x 20 in.

5940

=

1600
5940

=

.27gpm

28% Nitrogen

-

10.65 lbs. per gal.

-

1.13

32% Nitrogen

-

11.00 lbs. per gal.

-

1.15

20GPA x 4MPH x 20 in. x 1.13

5940

=

1808
5940

=

.31gpm

1. Snap Link (SL14)

8. 50 Mesh Poly Strainer (8079-PP-5O)

2. Breakaway Spring (SP4-6)

9. EPDM Gasket (CP19438-EPR)

3. 18635-111-406 – 3/8” QJ Body – Elbow

10. 8003VP Tip (TP8003VP)

4. 18636-112-406 – 3/8” QJ Body – Tee

11. Quick Jet Slotted Cap (25612-2-NYR)

5. T38 N

12. Center Section

6. NTT38 N

13. Left Arm Boom Pipe – 6’ Long

7. QJT-NYB Quickjet adapter

14. Right Arm Boom Pipe – 6’ Long

15. Boom Clamp (QJ111SQ-1) Not Shown