Danger, Water piping - mixing valve usage mixing valves, Figure 9 – State GS6 75 YRVHTL User Manual

Page 11

Advertising
background image

WATER PIPING - MIXING VALVE USAGE
Mixing Valves

Water temperature over

125°F can cause severe

burns instantly resulting in

severe injury or death.

Children, the elderly and the

disabled and are at highest

risk of scald injury.

Feel water before bathing or

showering.

Temperature limiting devices

such as mixing must be

installed when required by

codes and to ensure safe

temperatures at fixtures.

BURN

HOT

HOT

DANGER

Water heated to a temperature which satisfi es space
heating, clothes washing, dish washing, and other
sanitizing needs can scald and cause permanent injury
upon contact. Short repeated heating cycles caused by
small hot-water uses can cause a temperature increase of
the hot water by 20F° higher than the heater’s temperature
settings.

MIXING VALVE

SHUT-OFF

VALVE

SUGGESTED PIPING

ARRANGEMENT FOR

TOP CONNECTIONS

COLD-WATER

INLET

TEMPERED
POTABLE WATER

DISCHARGE
PIPE (DO NOT
CAP OR PLUG)

GAS
SUPPLY

TEMPERATURE-
PRESSURE
RELIEF VALVE

DRAIN
VALVE

METAL DRAIN

PAN 1.75”

MAX. DEPTH.

AT LEAST 2”

GREATER THAN

THE DIAMETER
OF THE WATER

HEATER.

6” MAX.
AIR GAP*

CERTAIN

MODELS ARE

EQUIPPED WITH

SIDE PLUMBING

CONNECTIONS

FOR SPACE

HEATING. THE HOT
AND COLD FITTING

ASSEMBLIES

(PART #9001262)

CAN BE ORDERED

THROUGH THE

MANUFACTURER

* NOTE: THE

T&P VALVE

DISCHARGE

PIPE MUST

BE PIPED

DIRECTLY TO

THE DRAIN

OR EXTERNAL

TO THE

BUILDING

MASSACHUSETTS: INSTALL A VACUUM RELIEF IN COLD WATER LINE
PER SECTION 19 MGL 142.

Figure 8.

his appliance has been design certifi ed as complying
with American National Standard/CSA Standard for water
heaters and certain models with side plumbing connections
are considered suitable for Water (Potable) Heating and
Space Heating. Note: Do not use in space heating only
applications.

The water supply pressure should not exceed 80 psi. If this
occurs, a pressure reducing valve with a bypass should be
installed in the cold water inlet line. This should be placed
on the supply to the entire house in order to maintain equal
hot and cold water pressures.

MIXING VALVE

SHUT-OFF

VALVE

SUGGESTED PIPING

ARRANGEMENT FOR

TOP CONNECTIONS

COLD-WATER

INLET

TEMPERED

POTABLE WATER

DISCHARGE
PIPE (DO NOT
CAP OR PLUG)

GAS

SUPPLY

TEMPERATURE-
PRESSURE
RELIEF VALVE

DRAIN
VALVE

METAL DRAIN

PAN 1.75” MAX.

DEPTH. AT

LEAST

2” GREATER

THAN THE

DIAMETER OF

THE WATER

HEATER.

6” MAX.
AIR GAP*

* NOTE: THE

T&P VALVE

DISCHARGE PIPE

MUST BE PIPED

DIRECTLY TO

THE DRAIN OR

EXTERNAL TO

THE BUILDING

MASSACHUSETTS:
INSTALL A VACUUM
RELIEF IN COLD
WATER LINE PER
SECTION 19 MGL
142.

NON-TEMPERED

WATER SUPPLY

NON-TEMPERED

WATER RETURN

Figure 9.

www.statewaterheaters.com

11