Installation and application – Armstrong World Industries ACUM185 User Manual

Page 24

Advertising
background image

AR-EXP-CUMMINS-07-00

OWNERS MANUAL


Item

Units

Type of Operation and Application

60 Hz

50 Hz

Prime

Standby

Prime

Standby

Engine

Rated Speed

rpm

1800

1500

Gross Engine Output

bhp (kWm)

252 (188)

277 (207)

219 (163)

241 (180)

BMEP

psi (kPa)

219 (1512)

241 (16620

190 (1314)

209 (1446)

Mean Piston Speed

Ft/s (m/s)

26.57 (8.1)

22.31 (6.8)

Cooling Sys-

tem

Ambient Air Temperature

°F (°C)

122 (50)

Engine Heat Reject to Coolant

BTU/min (kW)

6055 (107)

6630 (117)

4695 (83)

5415 (95)

Coolant Capacity

Gal (L)

3.25 (12.3)

Standard Thermostat Range

°F (°C)

180-203 (82-95)

Maximum Pressure Cap

Psi (kpa)

10 (69)

Maximum coolant friction

Psi (kpa)

5 (35)

4(28)

Fuel

System

Maximum fuel flow

gal/h (L/h)

55 (208)

Fuel Type

Diesel #2

Fuel Consumption @ 25% Power

gal/hr (L/hr)

3.20

3.52

2.69

2.96

Fuel Consumption @ 50% Power

gal/hr (L/hr)

6.41

7.04

5.38

5.92

Fuel Consumption @ 75% Power

gal/hr (L/hr)

9.61

10.56

8.07

8.88

Fuel Consumption @ 100% Power

gal/hr (L/hr)

12.81

14.08

10.76

11.85

Air Require-

ment

Combustion Air Flow

ft

3

/min (L/s)

540 (255)

550 (259)

407 (192)

437 (206)

Air Intake Restriction clean filter

In.H

2

O (kPa)

10(2.49)

Air Intake Restriction dirty filter

In.H

2

O (kPa)

25 (6.22)

Exhaust Temperature

°F (°C)

955 (513)

1055 (569)

996 (536)

1046 (563)

Maximun Allowable Back Pressure

In.H

2

O (kPa)

3 (10.13)

Lubrication

System

Maximum oil temperature

°F (°C)

250 (121)

Oil Pan Capacity

gal (L)

5.0 (18.9)

Total Engine Oil Cap. w/filter

gal (L)

6.3 (23.8)

Oil Filter Type

Cartridge

Lube oil specifications grade

SAE 15W - 40

Engine Elec-

tricals

Battery Charging Alternator

Volts, Ground

12V, negative

Baterry Charging Alternator

Rated amps

55

Recommended Battery Cold
Crank

CCA amps

1200 / 0 °F – 18 °C

Starter Motor

Volts, Ground

12V, negative

Operation

Temperature and Altidtude Losses

%

4% per 1000 ft (300 m) and 1% per 10°F (2% per 11°C)