Releasing the Balloon

In order to ensure 120 minutes of flight time, the radiosonde should be
launched within 15 minutes of battery connection.

Follow these steps to release the balloon:

1.

Make sure the balloon string is not tangled.

2.

Hold the unwinder to prevent the string from running out before the
release.

3.

Release the balloon and allow the radiosonde to lift from your
hand. Keep the string length between the radiosonde and the
unwinder as short as possible.

Checking the Reception

Immediately after the release, check the reception of the radiosonde
frequency on the receiver.

Proceed to monitor the sounding with the DigiCORA® Sounding
System.

Monitoring the Sounding with the DigiCORA®
Sounding System

If you have not already done so, enter the surface observation
information in the DigiCORA® Sounding System. Please refer to the
DigiCORA® User’s Guide for detailed instructions on using the
sounding software.