SPECIFICATIONS NITESTAR NS-50/60

POWER: 9 to 16 VDC, negative ground.

OPERATING TEMPERATURE: 0 degrees C to +70 degrees C.

DISPLAY: 1.0 ft. to 999,999 ft. Liquid Crystal W/ Backlight

DISTANCE RESOLUTION: + 1.0 ft.

ACCURACY: up to +/- 1 ft./MI

AUTOMATIC ERROR CORRECTION: (AEC)

KEYBOARD: Touch-Tell Silicon Rubber Keyboard,

Tone Verification w/Backlight

KEY FUNCTION: On/Off, Run/Hold, Display/Hold, Clear/Reset,

Mark/Enter, Calibrate, Unit, Pre-Distance, Up/Down,

Brightness, Print, Speed, Periodic Distance Interval, Program,

View, Numeric 0-9

PRE-DISTANCE: 0-999.999 in unit of measurement

SENSOR: Solid State Proximity, Transmission or Electronic Interface

BI-DIRECTIONAL: Compute distance count up or down.

PDI: Count Display, TTL Output, (12 VDC 1 Amp with P/N 1050)

DIMENSIONS: 7.5" (190.5mm) x 2.25" (57.15mm) x .88" (22.5mm)

CALIBRATION: Auto Calibration Entry / Manual

WEIGHT: 7.0 oz. • UNIT: Auto conversion Ft, Miles, Km

SPEED: 0-199 mph, Kph, fps

MEMORY: Two digit code (0-99),

Unlimited memory locations, Non-Volatile Type

MATERIAL CALCULATION: Area, Volume, Tonnage, Cost

SPECIFICATIONS NITESTAR (NS-60 ONLY)

COMMUNICATION: RS-232 In /Out

PRINTER: Serial Type

SELECTABLE BAUD RATE: (300-600-1,200-2,400-4,800-9,600)

INPUT: (1) 8 Bit 0-5 VDC Analog (1) Digital

OUTPUT: (1) Digital TTL Level

45

USING HYPERTERMINAL

Start Hyperterminal by launching your new Nitestar icon.
You can now issue the CAPTURE TEXT command to your NS-60.

To save all the NS-60 data to a file, select CAPTURE TEXT:

and then:

Pick the file name you want to save the text as.

This file will contain all your NS-60 data.