Installation – Avaya LUMULZMIC User Manual

Page 5

Advertising
background image

Figure 2. Back Panel Controls and Connectors

Installation

Note: Use shielded wire of no
smaller than 24 AWG, with runs
of 1000 feet or less.

Figure 3. Wiring Connections on Microphone Terminal Block

+

-

+

-

Output

G N D

O U T P U T

B U S Y
B U S S

C O N T A C T
C L O S U R E

G N D

O U T P U T

B U S Y
B U S S

C O N T A C T
C L O S U R E

G N D

O U T P U T

B U S Y
B U S S

C O N T A C T
C L O S U R E

G N D

O U T P U T

B U S Y
B U S S

C O N T A C T
C L O S U R E

SCREWDRIVER-ACCESSIBLE

VOLUME CONTROL

SWITCH FOR DEDICATED

SINGLE ZONE PAGING

COMPRESSION SCREW

TERMINAL BLOCK

CABLE CONNECTED TO

WALL SOCKET TRANSFORMER -

PROVIDES 12 VAC

Status Line

Normally Open

Contacts

Mic

Level

Control

Single Zone

Page

On

Off

The microphone has rubber feet for placing directly on a desktop. Connect
the transformer to a standard 120VAC 60 Hz wall socket. Figure 3 shows
the wiring connections at the microphone terminal block.